Use the dropdown filters on the right, to swiftly find your product... Left to right.
Product Code: TF974
PLEASE ENQUIRE FOR AVAILABILITY
This control box is the burner brain, it controls everything on the burner. It is suitable for many domestic burners, check manufacturer instructions for your burner to see if this is compatible.
For 1- or 2-stage oil burners up to 30 kg/h throughput and intermittent operation with or without oil preheating
Flame detection:
Photo resistor MZ 770 S Infrared-flicker detector IRD 1010 UV flame sensor UVD 970The TF 974 or TF 976 oil burner safety control boxes are suitable for oil burners which may be equipped with a oil preheater up to 30 kg/h capacity. The control boxes are approved and certified according to EN 230.
A special contact in the control unit short-circuits the thermo-switch of the fuel heater as soon as the burner is operating and the flame signal is present. Therefore interruption of the burner operation due to decreasing oil temperature can be prevented (e.g. in case of high oil flow).
If the control box goes into lock-out mode, the oil preheater power supply is also disconnected.
TYPES AVAILABLE
TF 974 1-stage operation post-ignition time ca. 20 sec. low voltage protection according to EN 230 TF 976 2-stage operation post-ignition time ca. 2 - 4 sec.low voltage protection according to EN 230Voltage (Volts) | 240 |
---|---|
Stage | Single |
Supply Voltage | 240v |
Fuel Valve Stages | Single |
Warranty | 12 Months |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |