VAT
Part Finder

Use the dropdown filters on the right, to swiftly find your product... Left to right.

Duct Transmitter

Product Code: DTR-CO2TH

Price
£170.00 ex. VAT £204.00 inc. VAT

PLEASE ENQUIRE FOR AVAILABILITY


Add To Favourites

The Flamefast BACnet sensor range can be supplied with any combination of Carbon Dioxide (CO2), Temperature & Relative Humidity, and the BACnet MS/TP interface allows for the sensors to be integrated with much larger systems over a simple two wire network.

As default the three 0-10V outputs will provide a full scale linear output for the CO2, Temp & RH levels, however these analogue outputs can be rescaled or configured to be controlled over the network, negating the requirement for separate local controllers.

There is also the option to assign each of the analogue outputs to any of the sensor values, and the on board relay can be configured to activate based on CO2, Temperature or RH levels, or all can also be controlled over the network.

This cost effective and versatile sensor is ideal for any application, including natural and demand controlled ventilation systems.

Key Features

  • 24V AC/DC Power Supply
  • Pluggable terminal block
  • Automatic object configuration
  • 3x 0-10V outputs (Network writeable)
  • Volt free contact output (Network writeable)
  • Typical 10+ year life expectancy
  • Self-calibrating CO2 sensor
  • Flanged enclosure with hinged lid for ease of installation
  • UK MANUFACTURED

Installer Selectable Options

  • CO2 Analogue output (2,000 / 5,000 ppm)
  • Relay set point (see below)

The unit has two user selectable programmes to control the volt free contact set point depending on the application.

Program Ventilation Gas Safety
Relay Position Normally Open Normally Closed
Relay Set Point   1,000ppm 4,500ppm
Power Supply 24V AC/DC
Power Consumption 50mA
Analogue Output 3 X 0-10V
VFC Output Rating SPDT - 100mA At 24V Max
CO2 Range 0 - 2,000 Ppm
CO2 Accuracy +/- 40 Ppm +3% At NTP
CO2 Sensing Method Non Dispersive Infra-red (NDIR)
CO2 Typical Sensor Life 10+ Years
Temp Range 0 - 50 DegC
Temp Accuracy +/- 0.3°C At 25°C
RH Range 0 - 100%
RH Accuracy +/- 2% At 20 - 80%
Operating Conditions Temp 0-50 DegC - Humidity 0-95% (NC)
Sampling Method Diffusion
Warm-up Time 30 Seconds
Housing Material Flame Retardant ABS - PC
IP Rating IP66
Approval CE
Probe Length(mm) 200
Height (mm) 152
Width (mm) 110
Depth (mm) 50
Warranty Period 5 Years
UK Mainland Order by 2pm for Next Day Delivery*